Welcome to Guangdong Qinglong Construction Engineering Co., Ltd.!
UHPC & GRC Complex Architecture Manufacturing
A Global Benchmark in Smart Architectural Fabrication
2026-01-03 18:08:00
Click:
The allowable deviation range for GRC exterior wall flatness, according to the requirements of the JGJ/T 322-2014 standard: panel surface flatness ≤3mm/2m, flatness at joints ≤1mm/2m, and overall facade verticality ≤H/1000 and ≤20mm. Strict flatness control is the key to ensuring the aesthetics and waterproofing performance of exterior walls.
Measurement methods: use a 2m straightedge and feeler gauge to check flatness, and a total station to check verticality. Through precise installation control, one project achieved flatness of ≤2mm/2m and joint straightness of ≤1mm/2m, with a clean and attractive facade. Installation error statistics show that 95% of measurement points meet the specification requirements.
Mold precision ≤1mm/2m, installation adjustment allowance ±5mm. Large-area panels are fitted with stiffening ribs to control deformation to ≤L/500.
Height difference between adjacent panel surfaces ≤1mm, using a dedicated joint control system. Joint width deviation ≤1.5mm to ensure sealant application quality.
Establish a survey control network with control points set on each floor. Use a laser plumb instrument to control cumulative error.
Acceptance is conducted in accordance with the GB 50210 specification, with a sampling ratio of no less than 5%. Professional instruments are used for measurement, ensuring objective and accurate data.
Flatness control requires whole-process management. From mold fabrication to installation adjustment, every step requires meticulous control.