Welcome to Guangdong Qinglong Construction Engineering Co., Ltd.!
UHPC & GRC Complex Architecture Manufacturing
A Global Benchmark in Smart Architectural Fabrication
2026-01-03 13:47:36
Click:
The mechanism by which steel bar corrosion causes GRC cracking is that rust expands in volume by 2-4 times, generating expansion stress of up to 30MPa. When the protective cover thickness is insufficient (<15mm) or compactness is inadequate, the corrosion-expansion stress exceeds the tensile strength of GRC (4-6MPa), resulting in cracks along the reinforcement, with crack width proportional to the corrosion rate.
Accelerated corrosion tests show that specimens with a 20mm protective cover developed 0.3mm cracks at a 5% corrosion rate, while specimens with a 15mm protective cover developed 0.5mm cracks at just a 3% corrosion rate. In one coastal project where sea sand was used (chloride ion content 0.08%), the steel bar corrosion rate reached 7% after 3 years of service, with cracks up to 1.2mm wide, making reinforcement work unavoidable.
Rust expands in volume by 2-4 times; expansion stress can reach 30MPa; these stresses cause cracking.
Each 5mm reduction in protective cover advances the cracking time by 40%; chloride ion content above 0.06% accelerates corrosion 3-fold; these data guide design.
Protective cover thickness ≥20mm; adding corrosion inhibitors (dosage 2%-3%); these technologies effectively prevent rust.
Half-cell potential testing; crack width monitoring; these methods enable timely detection.
Steel bar rust prevention is essential. Qinglong GRC's multiple protection ensures durability and safety.