Welcome to Guangdong Qinglong Construction Engineering Co., Ltd.!

Site Map   |  Contact Qinglong   | 

  • 中文
  • English
Qinglong UHPC & GRC

UHPC & GRC Complex Architecture Manufacturing

A Global Benchmark in Smart Architectural Fabrication

+86 760 8870 6348
+86 13902597531
Image display

UHPC & GRC Complex Architecture Manufacturing

A Global Benchmark in Smart Architectural Fabrication

UHPC & GRC Complex Architecture Manufacturing

A Global Benchmark in Smart Architectural Fabrication

UHPC & GRC Complex Architecture Manufacturing

A Global Benchmark in Smart Architectural Fabrication

UHPC & GRC Complex Architecture Manufacturing

A Global Benchmark in Smart Architectural Fabrication

UHPC & GRC Complex Architecture Manufacturing

A Global Benchmark in Smart Architectural Fabrication

UHPC & GRC Complex Architecture Manufacturing

A Global Benchmark in Smart Architectural Fabrication

资讯中心

ما المخاطر التي قد يسببها ارتفاع محتوى أيون الكلوريد في مواد GRC؟ وكيف يُتحكم فيه؟

2026-01-29 17:49:24

تصفح:

Controlling chloride ion content in GRC materials is a lifeline for structural safety and durability. Qinglong Group regards chloride ions as the "invisible killer" of GRC—excessive content can trigger a triple risk of steel reinforcement corrosion, fiber degradation, and matrix damage. According to GB/T 50476 (Standard for Durability Design of Concrete Structures), Qinglong's internal control standards are stricter than the national standard, requiring the water-soluble chloride ion content in GRC to be no more than 0.06% of the cementitious material mass. In the marine environment project of the Hainan International Convention and Exhibition Center, we ensured that 120,000 square meters of GRC roofing remained free of corrosion damage for ten years through strict chloride control, demonstrating the importance of scientific control.

The Mechanism and Hazards of Chloride-Induced Steel Corrosion

When GRC contains corrosion-resistant steel reinforcement or steel embedded parts, chloride ions destroy the passivation film and trigger electrochemical corrosion. Qinglong research shows that once chloride ion content exceeds the critical value (typically 0.05%–0.08%), the corrosion risk increases sharply. Corrosion products expand 3 to 7 times in volume, generating enormous internal stress that causes cracking and spalling of the GRC cover layer. In coastal areas, this risk is especially prominent, so chloride ion content must be strictly controlled.

The Corrosive Effect of Chloride Ions on Glass Fibers

Chloride ions react with cement hydration products to form Friedel's salt while releasing hydroxide ions, locally raising the pH value and intensifying alkali attack on glass fibers. Qinglong laboratory accelerated tests show that GRC specimens with excessive chloride ion content retained less than 70% of fiber strength after one year. This not only affects long-term mechanical performance but may also cause sudden component failure due to fiber embrittlement.

A Comprehensive and Systematic Chloride Control System

Qinglong has established a full-process chloride control system from raw materials to finished products: strict control of chloride ion content in raw materials such as sand, aggregates, and water; a strict ban on sea sand; selection of low-chloride admixtures; and regular cleaning of production equipment to prevent chloride accumulation. In the Wuhan Han Show Theatre project, we even applied deionization treatment to the mixing water to ensure chloride ion content was absolutely safe.

Testing and Monitoring of Chloride Ion Content

Qinglong laboratories are equipped with professional rapid chloride ion analyzers to conduct sampling tests on every batch of raw materials and finished products. We have also built a database of chloride ion content in raw materials, with focused monitoring of high-risk materials. For major projects, we additionally embed chloride ion detection sensors in components to achieve long-term monitoring. This all-round control system ensures the long-term safety of GRC components.

0
ما المخاطر التي قد يسببها ارتفاع محتوى أيون الكلوريد في مواد GRC؟ وكيف يُتحكم فيه؟
اضغط لفترة طويلة على الصورة للحفظ / المشاركة
文章推荐
Image display

Homepage     |    Products     |    Project Cases     |    News Center     |    Joins     |    About Us     |    Contact Us

 Company Address: Room 302, No. 22 Dongming Road, Shiqi District, Zhongshan City, Guangdong Province

Business Hotline: +86 760 8870 6348      Mobile: +86 13902597531

Email address: qlfsgrc@163.com

 

 Scan to add WeChat

Copyright © Guangdong Qinglong Construction Engineering Co., Ltd. All Rights Reserved  . Recordation Number: 粤ICP备13069248号-24

التشاور عبر الإنترنت

مرحبًا ، الرجاء النقر فوق خدمة العملاء عبر الإنترنت للتواصل عبر الإنترنت!

بيانات المتصل
Contact number
+86 13902597531
امسح رمز الاستجابة السريعة ضوئيًا
رمز الاستجابة السريعة
Scan with WeChat
  • إلغاء
Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
نسخ بنجاح!
Add WeChat friend to learn more about the product
I see.