Welcome to Guangdong Qinglong Construction Engineering Co., Ltd.!
UHPC & GRC Complex Architecture Manufacturing
A Global Benchmark in Smart Architectural Fabrication
2026-11-24 15:50:35
Click:
In engineering circles, searching for 'UHPC structural technical code' often returns contradictory answers: some say a national standard exists, some say only group standards exist, and others post a document whose number looks like an official text but was never actually published. For parties involved in design, drawing review, construction, supervision and procurement, this confusion is not merely an academic issue — a single wrong standard number in a design specification may, at the very least, get the drawings returned for review, and at worst leave no compliant basis at the acceptance stage.
Two data points can set the background first: according to public information from the UHPC Branch of the China Concrete and Cement-based Products Association (CCPA), domestic UHPC consumption in 2025 was approximately 230,400 cubic meters, up about 15% year on year, of which the building sector accounted for roughly 8%; and in 2025 the share of newly started prefabricated buildings nationwide already exceeded 30%. As consumption rises and applications expand, 'which text of the structural technical code should prevail' has become a question that cannot be avoided in 2026.

I. Conclusion First: 'UHPC Structural Technical Code' Is Not a Single Document Name
As of the information verifiable through public channels in early 2026, there is no current national standard in China whose title is exactly 'Technical Code for Ultra-High Performance Concrete Structures'. The current design basis directly related to 'UHPC structures' is the group standard T/CCPA 35—2022 (T/CBMF 185), 'Technical Specification for Structural Design of Ultra-High Performance Concrete (UHPC)', issued by the China Concrete and Cement-based Products Association and published on July 14, 2022.
In other words, when someone says 'design UHPC structures per the code', the accurate meaning of that sentence in 2026 is: for structural design methods, look at the association's structural design code; for material properties, look at the current national standard and the group testing standard; for testing of non-load-bearing components, look at the new national standard that took effect in 2025; and envelope components have their own corresponding group product standards. Four threads each govern one segment; put together, they form the complete chain of bases. The code map below lays out this chain in full.
II. The Code Map Master Table: Six Current, Usable Core Texts
Text number | Title | Level | What it governs | Status |
GB/T 31387—2015 | Reactive Powder Concrete | Recommended national standard | Material property baseline | Current, revision under review |
T/CCPA 7—2018 | Ultra-High Performance Concrete: Basic Properties and Test Methods | Group standard | UHPC grading, marking and test methods | Current |
T/CCPA 35—2022 (T/CBMF 185) | Technical Specification for Structural Design of Ultra-High Performance Concrete (UHPC) | Group standard | Structural design methods | Current, published 2022-07-14 |
GB/T 45594—2025 | Test Methods for Non-Load-Bearing Components of Ultra-High Performance Concrete | Recommended national standard | Testing of non-load-bearing components | In force from 2025-11-01 |
T/CBMF 171—2022 (T/CCPA 30—2022) | Ultra-High Performance Concrete (UHPC) Exterior Wall Panels | Group standard | Product requirements for envelope components | Current |
T/CBMF 172—2022 (T/CCPA 31—2022) | Ultra-High Performance Concrete (UHPC) Decorative Products | Group standard | Product requirements for decorative components | Current |
Reading this table requires clarifying two layers of relationships. First, different levels mean different modes of constraint: GB/T within national standards denotes a recommended national standard that carries no mandatory force in itself; group standards are voluntary in nature, but once written into contract clauses or design documents, they become binding on both contracting parties. Second, the division of roles differs: material standards govern 'whether the UHPC material itself qualifies'; the structural design code governs 'how components made with it are calculated and detailed'; product standards govern 'what a specific type of component must satisfy when leaving the factory'. Each of the three layers of bases has its own duty, and none can substitute for another.
III. In-Pipeline and Forthcoming: Three Texts That 'Look Like a Code' — Do Not Cite Them Yet
In-pipeline text | Public progress | Citation advice |
Technical Code for UHPC Curtain Wall Engineering | Project approved in September 2021; no published text seen via public channels | In design documents, write 'pending publication per the approved project plan'; do not invent a text number |
GB/T 31387 revision | The revision plan is under review; the official text has not been published | The current basis remains the 2015 edition; citations appearing online as 'GB/T 31387—2025' are erroneous citations |
National standard development plan for UHPC test methods | The development plan is advancing | Rely on real-time queries on the National Public Service Platform for Standards Information |
These three categories are the positions most often drawn incorrectly on the 'code map'. Project approval does not equal publication; a draft for comments does not equal a draft for approval; and a draft for approval still does not equal a current text. For projects in 2026, any text intended to be written into a design basis should first have its status verified once on the National Public Service Platform for Standards Information or on the issuing body's official website, so that the three labels — 'current, under review, pending publication' — are applied correctly.

IV. Correcting Common Mis-Citations: Three High-Frequency Pitfalls
Pitfall one: mis-citing JGJ/T 412—2017. Many online articles cite this industry standard number when discussing UHPC structures, but JGJ/T 412—2017 actually corresponds to a technical standard for vegetation-based slope protection, and has no correspondence with UHPC structural design. Once such a mis-citation enters an official design specification, it is unlikely to pass the drawing review stage.
Pitfall two: writing a group standard as a national standard. T/CCPA 35—2022 is a group standard; describing it in text as a 'national code' or 'national standard code' is a level-of-authority misstatement. The correct practice is to note the group standard status and the dual numbering (T/CCPA 35—2022, T/CBMF 185).
Pitfall three: applying the GRC standards system to UHPC. JC/T 940—2022 is an industry standard for GRC decorative products, and its impact resistance indicator is expressed in kJ/m³; the impact resistance and tensile indicator systems and dimensions of UHPC-related standards differ, so the two sets of values have no conversion relationship, and applying one to the other leads to wrong conclusions.
V. The Material Side: How T/CCPA 7—2018 and GB/T 31387—2015 Divide the Work
The layering of bases on the material side can be understood as follows: GB/T 31387—2015 provides the material property baseline for reactive powder concrete, while T/CCPA 7—2018 is specifically aimed at UHPC, providing grading, marking and the accompanying test methods.
T/CCPA 7—2018 contains two pieces of hard information useful for procurement. One is the grading and marking system: the compressive grade is denoted by UC plus a number, covering ranges such as UC120, UC150 and UC180; impermeability is denoted by UD, tensile performance by UT, and the material grade should be written as a complete mark rather than reporting only a compressive number. The other is the eligibility boundary: UHPC is characterized by fiber-based toughening, a point often summarized in the industry as 'no fibers, no UHPC' — a so-called UHPC that reports only high strength without any fiber mix proportion does not stand up under this standards system.
For material clauses in design documents, a dual-citation approach is recommended: cite both the material baseline of the current national standard and the grading marks of T/CCPA 7—2018, and then stipulate which set of test methods serves as the judgment basis. This way, no matter where the project is located, material acceptance will not be left hanging.
VI. The Structural Design Side: The Positioning and Boundaries of T/CCPA 35—2022
T/CCPA 35—2022 (T/CBMF 185), 'Technical Specification for Structural Design of Ultra-High Performance Concrete (UHPC)', is currently the text with the most direct correspondence to 'UHPC structures'. Its position is to provide a methodological basis for structural design, covering design paths for load-bearing capacity and serviceability limit states, material design values and detailing requirements; the specific clauses are subject to its officially published text.
Three boundaries should be remembered when using this code. First, it is a group standard whose binding force comes from citation: only when a design document states 'the UHPC structural design of this project shall follow T/CCPA 35—2022 (T/CBMF 185)' do the code's clauses take effect for the project. Second, it works in coordination with the general code system: the general baseline for structural design still follows the current national code system, while the UHPC code addresses specialized method issues — the two run in parallel without conflict. Third, the code does not replace test verification: for new types of joints and components, test data is usually needed beyond the code, which is also what the implementation links section below will discuss.
VII. Non-Load-Bearing Components and Envelope: The Testing Path After the New National Standard Took Effect in 2025
GB/T 45594—2025, 'Test Methods for Non-Load-Bearing Components of Ultra-High Performance Concrete', in force from November 1, 2025, fills the national-standard gap in test methods for UHPC non-load-bearing components. For non-load-bearing UHPC components such as curtain walls, exterior wall panels and decorative products, the testing basis now has a national-standard-level source, forming a paired relationship of 'product requirements plus test methods' with the group product standards.
The recommended combination at the project level is: for exterior wall panel components, cite T/CBMF 171—2022 (T/CCPA 30—2022) for product requirements and apply GB/T 45594—2025 for test methods; for decorative product components, cite T/CBMF 172—2022 (T/CCPA 31—2022) for product requirements and align test methods with the new national standard as well. Writing both layers clearly in the testing commission helps avoid a mismatch in caliber — 'which method to test by' — between the commission form and the report.
VIII. Regional Standard Differences: The Same Type of Component, Different Requirements in Different Places
Beyond national and group standards, multiple provinces have issued UHPC-related local standards (for example, Shandong's DB37/T 4874—2025), covering different stages such as design, construction or component application. The specific list of local standards and their current status are subject to what the provincial housing and urban-rural development authorities publish.
For cross-regional projects, a merged strategy is recommended: compare the local requirements of the project location item by item against national and group standard requirements, determine the governing caliber on the principle of 'the stricter requirement prevails', and state in the design specification the order of precedence among the cited texts. Note that the scope of application of a local standard is usually limited to its own administrative region; directly copying one province's local standard clauses for a project elsewhere is neither necessary, and may conflict with local drawing review calibers.
IX. Overseas Projects: System Switching and Text Selection
Overseas projects cannot default to domestic texts. For export or overseas construction projects (for example, component supply for the Malaysian, Southeast Asian or Middle Eastern markets), the design basis follows the system specified in the contract — Eurocode, American standards or local standards each have complete material and design systems, and domestic standard texts generally serve as technical reference rather than direct basis. Writing clearly in the contract 'design calculations and tests shall follow such-and-such system, and material marking shall follow such-and-such' is far more effective than arguing about the basis afterward.
One additional piece of public information related to Hong Kong, China: in December 2025, Hong Kong, China published an English-language local standard text related to UHPC, providing a localized basis for local projects. For projects in Hong Kong, China and other overseas English-language contexts, text selection is governed by the contract and local regulations.

X. Five Citation Disciplines
Whether writing a design specification, bidding document or testing commission form, the following five disciplines can be applied directly:
1. Cite current texts, not in-pipeline ones. Texts in the approval, comment-solicitation or submission-for-approval stages must never be given a number in official documents; write only a progress description.
2. Cite texts down to the year, and down to the clause number whenever possible. Vague wording such as 'per the relevant codes' is a common source of later disputes.
3. State levels of authority accurately. National, industry, group and local standards each carry their own status; do not write a group standard as a national standard, and do not write a local standard as a nationwide basis.
4. Recommended standards take effect only through citation, and the mode of taking effect must be stated. GB/T standards are themselves recommended; design documents should state 'such-and-such standard is adopted as agreed in the contract' or list it directly as a design basis, so that the binding force has a clear source.
5. Drafter and participating organization information is subject to the official text. Any statement about 'who participated in which code' should be checked back against the list of drafting organizations and principal drafters in the official standard text — no retelling, no inference.
XI. The Three-Part Writing Method for Basis Clauses
To put the citation disciplines into words, the recommended approach is the three-part 'standard layer — indicator layer — judgment layer' writing method:
• Standard layer: state the complete number and title of the basis text, e.g. 'material properties shall follow GB/T 31387—2015 'Reactive Powder Concrete' and T/CCPA 7—2018'.
• Indicator layer: state the grade marks and value ranges of specific indicators, e.g. 'the UHPC strength grade shall be no lower than UC120, with impermeability and tensile grades per the complete marks specified in the design documents'.
• Judgment layer: state the test methods and judgment rules, e.g. 'test methods shall follow GB/T 45594—2025; judgment shall be based on reports issued by a qualified testing institution, with the witnessed sampling ratio per current witnessed sampling management requirements'.
Each part governs one thing: where the basis comes from, what the indicators are, and how to verify. When reviewers and supervisors see this structure, they can directly locate the source of every sentence; when a dispute arises, they can trace back through the clause number to the original text.
XII. Implementation Links from Design to Construction
Writing the code into the design documents is only the starting point; landing the work involves four implementation links:
Link | Key points | Basis clues |
Detailed design | Component joints, connection nodes and embedded part positioning are deepened on top of the construction drawings; connection detailing with the main structure is issued as separate node drawings | Design documents and the accompanying clauses of the structural design code |
Test verification | New types of joints and components undergo trial mixes and verification tests per design requirements; reports are archived with the technical documentation | GB/T 45594—2025 and the product standards |
First article inspection (FAI) | Before batch production, a first article inspection (FAI) is performed; dimensions, appearance and mechanical indicators are compared item by item | Product standards and contract stipulations |
Witnessed testing | The testing commission entity and witnessed sampling procedures follow current management requirements; the witness ratio is no lower than the relevant provisions | MOHURD Order No. 57 (commission entity); Jian Jian [2000] No. 211 (witnessed sampling) |
The witnessed sampling link deserves separate emphasis: under the current management caliber of Jian Jian [2000] No. 211, the witnessed sampling ratio is no lower than 30%; the qualification of the entity commissioning testing follows MOHURD Order No. 57. These two items are unrelated to the standard texts themselves, yet they determine whether the testing report is accepted at project acceptance.
XIII. Verification Demo of a Company's 'Participating Organization' Claim
Using Guangdong Qinglong Construction Co., Ltd. as a demonstration sample, here is how a claim such as 'participating organization' is verified: the company is a manufacturer of UHPC (ultra-high performance concrete) and GRC components, with Song Dunqing as founder, founded in 1997, operating three production bases in Guangdong, Guangxi and Malaysia, with project experience at home and abroad. Companies in the industry are often described as 'participating organizations of industry standards'; the verification method for such claims is: go back to the official text of the standard and check the lists of drafting organizations and principal drafters.
Taking the GRC application technical standard JGJ/T 423—2018 as an example, the participating organizations column of its official text registers 'Guangxi Qinglong Chemical Building Materials Co., Ltd.', and the list of principal drafters includes 'Song Dunqing' — when citing, check the original official text and note that the entity involved is the name as registered in the text; it is inappropriate to equate companies outside that list directly with the standard. The participation status of UHPC-related group standards is verified the same way. Note: the company information serves only as a demonstration sample of the verification method and does not constitute a recommendation of any company; details of the three bases and project experience are subject to the company's official channels.
Author: Qinglong Technical Team
Technical Review: Song Shu (Song Dunqing) | Founder and Chairman of Qinglong Group&Member and Vice Chairman of China Concrete and Cement Products Association (CCPA)