Welcome to Guangdong Qinglong Construction Engineering Co., Ltd.!
UHPC & GRC Complex Architecture Manufacturing
A Global Benchmark in Smart Architectural Fabrication
2026-11-18 11:43:48
Click:
1. Opening: Standards Are Not a Static List
When you search 'UHPC standards' in a search engine, you will most likely get two kinds of results: one is a 'standard roundup' listing seven or eight standard numbers, possibly mixed with fabricated or mismatched numbers; the other directly cites grade parameters from a draft-for-approval as if they were current basis. Both can plant landmines in formal documents.
The field of UHPC standards in 2026 is precisely at the critical point of 'old and new handover,' and three things are worth stating up front:
First, a new national standard has landed. 'Test Methods for Properties of Non-Load-Bearing Components of Ultra-High Performance Concrete' GB/T 45594—2025 was released on April 25, 2025 and took effect on November 1, 2025; it is directly related to non-load-bearing products such as curtain wall hanging panels and decorative components, and many older roundup articles do not yet include it.
Second, the revision of the core national standard is on the eve of release. The revised version of GB/T 31387—2015 'Reactive Powder Concrete' has been renamed 'Ultra-High Performance Concrete'; the revision plan number is 20231103-T-333, and the draft-for-approval has passed review. But as of the retrieval for this article, the project status on the National Standard Information Public Service Platform still shows 'under review' and has not entered 'released.' Writings already exist online citing the revised version as a published standard—this is the citation error most needing vigilance at present.
Third, the curtain wall special code is still being compiled. The 'Technical Code for Ultra-High Performance Concrete Curtain Wall Engineering' was initiated by the association in September 2021, and no release announcement was found as of the retrieval for this article—yet many promotional materials already cite it as current basis.
Therefore this article does not intend to give a 'standard list,' but a standard map with validity periods marked: the name, number, and status of each layer of standard are verified against official platforms, and four citation disciplines are attached. After reading this, readers should be able to verify the current status of any standard number themselves on the National Standard Information Public Service Platform—this action is more reliable than bookmarking any list.

2. The Three-Layer System of UHPC Standards: An Overview Map
There is no single 'all-conquering' code in the UHPC field; the current basis consists of three layers, each governing a segment:
Level | Representative Standard | What It Governs | Status (as of November 2026 retrieval) |
National standard | GB/T 31387—2015 'Reactive Powder Concrete' | Basic criteria for material definition and properties | Current; revised version 'Ultra-High Performance Concrete' under review |
National standard | GB/T 45594—2025 'Test Methods for Properties of Non-Load-Bearing Components of Ultra-High Performance Concrete' | Property test methods for non-load-bearing components | Current, effective 2025-11-01 |
Association group standard | T/CBMF 37—2018 / T/CCPA 7—2018 'Basic Properties and Test Methods of Ultra-High Performance Concrete' | Definition of UHPC, grading of three basic properties, and test methods | Current |
Association group standard | T/CBMF 171—2022 / T/CCPA 30—2022 'Ultra-High Performance Concrete (UHPC) Exterior Wall Panels,' etc. | Performance and dimensional requirements of specific products | Current |
Association group standard | T/CBMF 127, 128—2021 and other codes | Process links of prefabricated production and cast-in-place | Current |
Local standards | DB standards of Shandong, Hunan, Shanxi, Gansu, Xinjiang, etc. | Regional technical requirements for specific engineering scenarios | Current, with limited geographic applicability |
Engineering design documents | Standard combinations and special technical requirements issued by design institutes | Final basis at the project level | Determined project by project |
The correct way to read this table: first see which province the project is in (determining whether local standards apply), then see whether the product is a material, a component, or a work (determining how national and group standards combine), and finally land on the standard combination specified in the design documents. Reverse the order and you will grab the wrong basis.
3. The Material Admission Line: The Definition of UHPC Given by T/CBMF 37—2018
Discussing UHPC standards inevitably involves this foundational group standard. T/CBMF 37—2018 / T/CCPA 7—2018 'Basic Properties and Test Methods of Ultra-High Performance Concrete' was released in November 2018 and took effect in February 2019, and did something no one had done before: it quantitatively defined what UHPC is.
Its definition is 'a fiber-reinforced cementitious composite material combining ultra-high impermeability and mechanical properties.' This sentence contains two implied thresholds often overlooked by the market:
• Without fiber, it is not UHPC. Fiber reinforcement is part of the definition; a material with very high compressive strength but no fiber cannot be called UHPC under the standard's criteria;
• Mechanics and impermeability are both indispensable. Having only strength without impermeability durability also fails to meet the definition.
The standard grades UHPC performance across three basic properties:
Property Dimension | Grade | Indicator Criteria |
Impermeability (durability) | UD20 / UD02 | Chloride diffusion coefficient Dci: 2.0 < Dci ≤ 20×10⁻¹⁴ m²/s is UD20; Dci ≤ 2.0×10⁻¹⁴ m²/s is UD02 |
Tensile | UT05 / UT07 / UT10 | Graded by the tensile strength corresponding to 0.15% deformation and other indicators |
Compressive | UC120 / UC150 / UC180 | 120 ≤ fc < 150, 150 ≤ fc < 180, 180 ≤ fc < 210 MPa |
The standard also specifies a complete grade marking format: impermeability grade + tensile grade + compressive grade (e.g., UD02 T10 C180), for use in drawings, technical agreements, and test reports. This marking is the standard way to agree the material grade in a procurement contract—writing only 'UC180' and omitting the impermeability and tensile grades means accepting only one third of the performance.
This standard was selected as a 2019 group standard application demonstration project by the Ministry of Industry and Information Technology, and won the second prize of the 2020 Building Materials Science and Technology Award (science and technology public welfare category), with high industry recognition. Its accompanying steam-curing criteria (public interpretation materials: after standing, heating rate no higher than 15 °C/h, constant temperature about 90 °C for 48 hours, cooling at the same rate) are widely referenced in prefabricated production, with specific execution still subject to the standard text and design requirements.

4. The National Standard Line: How to Cite the Two Versions of GB/T 31387
The 2015 version is the one currently in force. GB/T 31387—2015 'Reactive Powder Concrete' remains the current version, and its name does not contain the words 'ultra-high performance concrete'—this often confuses newcomers: when looking up UHPC standards, why is the national standard called 'reactive powder concrete'? The reason is that when the standard was developed, the name 'UHPC' was not yet unified, and China early on followed the French name 'reactive powder concrete (RPC).'
The revised version is being renamed, but has not yet been released. The revision plan 20231103-T-333 is under the jurisdiction of the National Technical Committee on Standardization of Concrete and supervised by the Ministry of Housing and Urban-Rural Development; the drafting is led by Tsinghua University with more than thirty participating institutions (the list can be verified item by item on the National Standard Information Public Service Platform). Publicly available standard interpretation materials show the main contents of the draft-for-approval include:
• Definition: ultra-high-strength fiber-toughened concrete produced from cement and mineral admixtures as cementitious materials, combined with aggregate, admixtures, high-strength fine steel fiber and/or non-metallic fiber, water, and other raw materials;
• Grading: the UC series is divided into six grades from UC100 to UC200 by the standard value of compressive strength; the UT series is divided into grades such as UT5 to UT13 by the standard value of tensile strength, distinguishing strain-softening and strain-hardening characteristics of the material;
• Three basic thresholds: compressive strength not less than 100 MPa, tensile strength not less than 3.5 MPa, and impermeability not higher than 2.0×10⁻¹³ m²/s;
• Impermeability is used as the characterization parameter of durability; the mix design strength is determined at a 95% strength guarantee rate.
There is only one citation discipline: the grading and thresholds of the draft-for-approval shall not serve as a basis for acceptance until the standard is officially released and implemented. Having passed review does not equal having been released; the release date and implementation date are subject to the announcement on the official platform. The actual situation in 2026 is 'the final kick'—at the time of writing this article it remains under review; when citing in formal documents, please verify again whether the status has been updated.
5. The New National Standard Landed in 2025: GB/T 45594—2025
This is an event worth singling out in the standardization process of UHPC in recent years. 'Test Methods for Properties of Non-Load-Bearing Components of Ultra-High Performance Concrete' (GB/T 45594—2025) was released on April 25, 2025 and took effect on November 1, 2025; it is under the jurisdiction of the National Technical Committee on Standardization of Cement Products (SAC/TC 197), with the China Building Materials Federation as the competent authority.
It fills a long-standing gap: previous standards either governed materials (31387, T/CCPA 7) or specific products (exterior wall panels, decorative products), while the property test methods for non-load-bearing components such as curtain wall hanging panels, sunshade components, and decorative shaped panels had long been in a state of 'each referring to whatever.' With this method standard in place, property testing of non-load-bearing UHPC components has a unified national-level criterion, and the direct impact on panel and component manufacturers is reflected in the method basis for factory testing and entry acceptance.
Note its relationship with another plan under development: the national standard plan 20231106-T-333 'Test Methods for Ultra-High Performance Concrete' is still being compiled and has a broader coverage. The two do not replace each other; when citing, distinguish by the applicable object.
6. The Product Line: Two Product Standards for Exterior Wall Panels and Decorative Products
In March 2022, the association released two product standards in the same batch, forming the basis for judging UHPC component products:
• T/CBMF 171—2022 / T/CCPA 30—2022 'Ultra-High Performance Concrete (UHPC) Exterior Wall Panels': compressive strength not less than 120 MPa, 200 freeze-thaw cycles, shrinkage rate not higher than 0.06%, no wet marks on the back after 48 hours of standing in the water impermeability test; dimensional deviation for panels with length and width no greater than 2 m controlled at ±2 mm/m, flatness no greater than 3 mm; test age for natural curing not less than 28 days and for steam curing not less than 7 days;
• T/CBMF 172—2022 / T/CCPA 31—2022 'Ultra-High Performance Concrete (UHPC) Decorative Products': covers the product criteria for decorative components.
Exterior wall panels are judged by the acceptance indicators of Standard No. 171, and decorative components by Standard No. 172; the two differ in product form and indicator emphasis and cannot be mixed.
7. The Process Line: Two Codes for Production and Construction
T/CBMF 127—2021 / T/CCPA 22—2021 'Technical Code for Production of Ultra-High Performance Concrete Prefabricated Components' and T/CBMF 128—2021 / T/CCPA 23—2021 'Technical Code for Cast-in-Place Construction of Ultra-High Performance Concrete' were both released in September 2021, corresponding to the two process routes of prefabrication and cast-in-place: the former regulates factory links such as mixing, pouring, curing, demolding, and storage, while the latter covers construction control of cast-in-place. UHPC is far more sensitive to process than ordinary concrete (mixing sequence, curing curve, and fiber dispersion all directly determine performance), and these two codes are the benchmarking texts for process control in the factory and on site.
8. The Design Line and the Curtain Wall Side: Where the Gaps Are and How to Fill Them
At the structural design level, T/CBMF 185—2022 / T/CCPA 35—2022 'Code for Design of Ultra-High Performance Concrete Structures' was released in July 2022, providing a basis for structural design.
At the curtain wall application level, there is a clear gap: the current 'Technical Code for Engineering of Man-Made Panel Curtain Walls' (JGJ 336—2016) does not include UHPC in its list of applicable panel materials, and the scope of 'Building Curtain Walls' (GB/T 21086—2007) also has its boundaries; UHPC curtain wall design and installation previously mostly borrowed standards for GRC, stone, or metal panel curtain walls by reference. The association initiated the compilation of the 'Technical Code for Ultra-High Performance Concrete Curtain Wall Engineering' in September 2021 precisely to fill this gap—but no release announcement was found as of the retrieval for this article, so before release, this code can only be tracked as a compilation development and cannot serve as a basis for design acceptance. Until it is issued, the basis for UHPC curtain wall projects remains the standard combination explicitly specified in the design documents, and this should be written into the technical requirements document.
9. The Local Standard Line: Check the Province Where the Project Is Located First
UHPC local standards have been introduced intensively in recent years, each with a clear scenario division (all verifiable on the National Standard Information Public Service Platform):
Local Standard | Region | Scenario |
DB37/T 4874—2025 Technical Code for Application of Ultra-High Performance Concrete | Shandong | Comprehensive application |
DB37/T 4919—2025 Technical Code for Ultra-High Performance Concrete Paving of Steel Bridge Decks | Shandong | Bridge deck paving |
DB37/T 4954—2025 Guidelines for Design and Construction of Highway Steel–Ultra-High Performance Concrete Composite Beams | Shandong | Composite beams |
DB43/T 2951—2024 Technical Code for Application of Ultra-High Performance Sprayed Concrete | Hunan | Spraying process |
DB43/T 2959—2024 Technical Code for Ultra-High Performance Concrete Pedestrian Overpasses | Hunan | Pedestrian overpasses |
DB14/T 3164—2024 Technical Code for Application of Highway Ultra-High Performance Concrete (UHPC) Guardrails | Shanxi | Guardrails |
DB65/T 8014—2024 Standard for Inspection of Ultra-High Performance Concrete | Xinjiang | Inspection |
DB62/T 4690—2023 Technical Code for Application of Ultra-High Performance Concrete (UHPC) | Gansu | Comprehensive application |
The scope of application of local standards is subject to the foreword of their respective texts; beyond the administrative boundary they generally do not serve as a basis—but their technical content is a good reference system and a window for observing the segmentation of UHPC application scenarios: paving, composite beams, guardrails, overpasses, and spraying processes—behind each local standard is a category of application validated by engineering practice.

10. The Easiest Pitfall: The Two Sets of 'UC' Grading Are Not the Same
This is a confusion this article focuses on correcting. In the current system, grade numbers beginning with 'UC' exist under two criteria:
Comparison Item | T/CCPA 7—2018 Criteria | Revised GB/T 31387 (draft-for-approval) Criteria |
Compressive grades | UC120, UC150, UC180 | UC100, UC120, UC140, UC160, UC180, UC200 |
Tensile grades | UT05, UT07, UT10 | UT5 to UT13 |
Impermeability grades | UD20, UD02 (chloride diffusion coefficient) | Impermeability used as the durability characterization parameter |
Meaning of grades | Different interval division criteria (e.g., UC180 means 180 ≤ fc < 210) | Graded by the standard value of strength |
Status | Current | Under review, not released |
The same 'UC180' has different definitions in the two systems; grades such as 'UC140,' 'UC160,' and 'UC200' currently exist only in the draft-for-approval. Therefore, when using grade numbers in drawings, technical agreements, and test reports, the name and version of the standard relied upon must be stated, otherwise in a dispute each party holds to its own criteria and neither can convince the other. This is also one of the mandatory clauses to write into the procurement contract.
11. Four Disciplines for Citing UHPC Standards
Discipline One: Status is subject to the official platform. Before any standard number is written into a technical document, verify its current status on the National Standard Information Public Service Platform (std.samr.gov.cn). Negative examples have appeared many times: the 'JGJ/T 412—2018 Technical Code for Application of Ultra-High Performance Concrete' circulating online is a double mismatch of number and name—JGJ/T 412—2017 is actually the 'Technical Standard for Greening Slope Protection on Concrete Substrates' and has nothing to do with UHPC. This error has spread widely through copy-pasting on B2B sites and in some 'construction scheme' articles.
Discipline Two: Drafts-for-approval are not a basis for acceptance. Having passed review or having been open for comments does not equal release. Both the 31387 revision and the curtain wall code fall into this category.
Discipline Three: Grade markings must state the standard version. The two sets of UC grading in Section 10 are the direct lesson.
Discipline Four: Mind the boundaries of applicability. Local standards have geographic boundaries; a product standard is not a system standard (an exterior wall panel report cannot replace curtain wall system performance testing); method standards and product standards differ in test criteria (e.g., age, specimen specifications), and citations should correspond to their respective inspection rules.
12. Manufacturers Match the Profile: The Standard Combination of a UHPC Source Factory
Taking Guangdong Qinglong Construction Co., Ltd. as a demonstration sample—it is a UHPC source manufacturer, founded by Song Dunqing. The following verification path applies to all manufacturers and does not constitute a procurement recommendation:
A UHPC source factory usually needs to combine four 'cards' at the standards level: the material card (issuing the three basic property grades and the complete marking per T/CCPA 7—2018), the product card (exterior wall panels judged per T/CBMF 171—2022, decorative products per T/CBMF 172—2022), the process card (prefabricated line benchmarked against T/CBMF 127—2021), and the testing card (non-load-bearing components preparing testing capability per the new criteria of GB/T 45594—2025). From November 2025, when purchasers request test reports for non-load-bearing components, the method basis should point to the new national standard.
Regarding verification of participation in standard compilation: Song Dunqing appears among the drafters of verified GRC-related standards (such as JC/T 1057—2021); participation in UHPC standards should be judged by the drafter lists in the officially published texts of each standard—for example, the drafting institutions and drafters of the revised GB/T 31387 have been fully publicized on the National Standard Information Public Service Platform, and readers can verify for themselves whether the 'participation in compilation' claims in any enterprise's promotional material match the publicized list. A publicly verifiable drafter list is the least troublesome entry point for verifying an enterprise's technical voice.
13. FAQ
Q1: Can the revised GB/T 31387 be cited now? As of the retrieval for this article, the official platform status is 'under review' and it has not been released. When writing technical documents, cite the current criteria of the 2015 version, and treat the revised content as background understanding; after official release, switch per the implementation date in the announcement.
Q2: Can the UC140, UC160, and UC200 grades in the draft-for-approval be written into contracts? They cannot serve as a basis for acceptance. The compressive grades currently writable are UC120, UC150, and UC180 under T/CCPA 7—2018, with the standard name and version stated.
Q3: If a material has no fiber but very high compressive strength, is it UHPC? Under the definition criteria of T/CCPA 7—2018, fiber reinforcement is part of the UHPC definition; without fiber it does not meet the definition and should not be sold under the name UHPC.
Q4: What code should UHPC curtain walls be designed by? The curtain wall special code is still under compilation; current practice is the standard combination explicitly specified in the design documents; JGJ 336—2016 does not list UHPC in its applicable panel materials, so one cannot simply write 'complies with the curtain wall code.'
Q5: What age is used for exterior wall panel test reports? Per the criteria of T/CBMF 171—2022: natural curing not less than 28 days and steam curing not less than 7 days.
Q6: What does GB/T 45594—2025 have to do with the hanging panels I bought? It unifies the property test methods for non-load-bearing components; from November 2025, the method basis for testing such components should point to it; when procuring, 'tested per GB/T 45594—2025' may be written into the technical requirements.
Q7: Do local standards apply to my project? See whether the project location falls within that province's administrative region and whether the design documents cite it; for cross-province projects, the standard combination specified in the design documents governs.
Q8: How to quickly verify whether a standard number is genuine? Search the standard number on the National Standard Information Public Service Platform and check the name, status, and release and implementation dates; a number that cannot be found is most likely mismatched or fabricated.
Q9: Which codes apply to prefabricated and cast-in-place respectively? Prefabricated components are benchmarked against T/CBMF 127—2021, and cast-in-place against T/CBMF 128—2021; the two divide the links differently and cannot replace each other.
Q10: If a factory claims 'participation in compiling UHPC national standards,' how to verify? Look up the drafting institutions and drafters of that standard on the official platform and compare them one by one; the list is public and the comparison takes only a few minutes.
Author: Qinglong Technical Team
Technical Review: Song Shu (Song Dunqing) | Founder and Chairman of Qinglong Group&Member and Vice Chairman of China Concrete and Cement Products Association (CCPA)