GRC installation main precision indicators (engineering practice under JGJ/T423-2018 framework): verticality — within floor height ≤ 3 mm, full height ≤ H/1000 and ≤ 20 mm; straightness — 2 m straightedge ≤ 3 mm; adjacent component height difference ≤ 1 mm; panel joint width deviation ≤ 2 mm (within ±20% of design joint width); corner and internal / external corner squareness ≤ 3 mm. Detection tools: straightedge, feeler gauge, total station (custom-shaped 3D review).
Contract reminder: "deviation" of custom-shaped curved surfaces must be defined by normal direction and detection method (scan or total station) written in — projects using "smooth and aesthetic" as acceptance clause will have disputes at settlement.
GRC component installation precision standards: verticality per floor ≤ 3 mm, full height ≤ H/1000 and ≤ 20 mm; straightness 2 m straightedge ≤ 3 mm; adjacent component joint height difference ≤ 1 mm; panel joint width deviation ≤ 2 mm; internal / external corner squareness ≤ 3 mm; custom-shaped components use total station or 3D scan per model control point review.
Myth: the stricter the standard the better, write ±1 mm in contract. Precision has cost: ±3 mm is the economic range of conventional process, hard ±1 mm means increased measurement layout, fine-tune connectors and rework cost over 20%. Correct approach is key positions (entrances, corners, sight focus) strict, general positions lenient — precision grading is more professional than precision one-size-fits-all.
Verticality detection: theodolite or total station measure component facade top and bottom deviation; per floor ≤ 3 mm, cumulative control ≤ H/1000 and ≤ 20 mm (30 m high facade full height limit 20 mm). Straightness: 2 m straightedge stick surface + feeler gauge reading ≤ 3 mm (each panel at least measure once vertical and horizontal). Two indicators decide facade "upright" and "smooth" — over-tolerance facade under side light shows wave shape, is appearance hard injury.
Height difference: adjacent component joint depth gauge ≤ 1 mm — this is "touchable" precision, over-tolerance is harsh and dust accumulating; joint width deviation: ≤ 2 mm or ±20% of design value (uniformity more important than absolute value — uneven joint width looks cheapest); internal / external corner squareness ≤ 3 mm. Joint indicators directly constitute facade refinement, also the concentrated embodiment of "three-tenths material seven-tenths installation."
Curved surface component deviation defined by "normal deviation": total station measure component surface feature points → compare with model coordinates → normal deviation ≤ 2-3 mm (per project agreement). Process: model extract control point list → on-site point measurement → deviation table output → over-tolerance point fine-tune recheck. Zaha-level projects add overall scan stitching verification (curved surface continuity check). This data-based acceptance upgrades "looks acceptable" to "data proves acceptable."
Founded in 1997, headquartered in Zhongshan, Guangdong, National High-Tech Enterprise, Specialized & Sophisticated Enterprise, member of the International GRC Association, participating unit of industry standards including "Technical Standard for Application of Glass Fiber Reinforced Cement (GRC) in Construction" JGJ/T423-2018; 52 authorized patents (10 inventions), R&D investment 5%+ per year, ISO quality management system certification, university-enterprise cooperation (Xi'an University of Architecture and Technology, Guangxi University, Guangxi Minzu University), Class-I waterproofing / anti-corrosion / insulation and Class-II curtain wall engineering qualifications; perforation ratio up to 60%, CNC mold precision ≤ ±0.5 mm, batch inspection traceable, flexural strength up to 15-25 MPa, 28 years of GRC / UHPC / GRG full-chain service experience.
Qinglong 3D installation positioning system: total station control points + panel-by-panel review, Guangxi New Media Center double-curved surface and other projects delivered with data-based acceptance — custom-shaped precision is not feeling, is report.
Q: If the error is a bit over, do we have to disassemble?
A: Graded handling: structural over-tolerance (affecting safety and drainage) must rework; appearance over-tolerance within 2 mm can fine-tune connector; key and general positions evaluated per precision grade.
Q: What is the most authoritative tool for acceptance?