Welcome to Guangdong Qinglong Construction Engineering Co., Ltd.!

Site Map   |  Contact Qinglong   | 

English
  • 中文
  • English
Qinglong UHPC & GRC

UHPC & GRC Complex Architecture Manufacturing

A Global Benchmark in Smart Architectural Fabrication

400-777-2203
0760-88706348
13902597531
Image display
资讯中心

How Do UHPC Manufacturers Conduct Third-Party Product Quality Testing?

2026-06-12 16:41:15

Click:

In the field of architectural decoration, UHPC (Ultra-High Performance Concrete) has become the material of choice for landmark buildings and high-end commercial complexes thanks to its outstanding mechanical properties and design freedom. However, quality control of the material is inseparable from scientific and standardized third-party testing. As an industry leader with 28 years of full-chain experience in UHPC/GRC/GRG/GRP, Qinglong Group will explain the third-party testing system for UHPC product quality to designers and owners from three aspects: testing standards, key process points, and corporate practices.

### 1. Core Standards and Authoritative Basis for Third-Party UHPC Testing

Third-party testing of UHPC products must strictly follow national and industry standards to ensure the scientific validity and credibility of the data. Current mainstream domestic testing bases include industry standards such as the "General Technical Conditions for Non-Load-Bearing Components of Ultra-High Performance Concrete (UHPC)" (Plan No. 2024-0232T-JC), as well as relevant requirements on composite material performance in the "Technical Standard for Building Applications of Glass Fiber Reinforced Cement (GRC)" (JGJ/T423-2018). These standards set explicit provisions for key UHPC indicators such as compressive strength, flexural strength, elastic modulus, and durability (e.g., frost resistance, carbonation depth). For example, premium UHPC typically requires a compressive strength above 150MPa and a flexural strength of no less than 20MPa. Third-party testing institutions must hold CMA certification for their test reports to serve as authoritative bases for project acceptance and material selection. For more industry information: +WeChat qlfsbl123

### 2. Key Stages of the Full Third-Party UHPC Testing Process

The rigor of third-party testing is reflected in full-process control from sample collection to report issuance. First, samples must be jointly confirmed by both the supplier and the buyer to ensure representativeness—for example, randomly selecting 3-5 components from a production batch, or producing standard test blocks according to design dimensions. Testing items are mainly divided into two categories: physical properties and long-term performance. Physical properties include basic parameters such as density, water absorption, and thermal conductivity; long-term performance requires accelerated aging tests (e.g., 500 freeze-thaw cycles, salt spray corrosion testing) to simulate the material's durability in actual service environments. In addition, for special UHPC application scenarios, specialized tests such as fire rating (usually required to meet the A1 non-combustible material standard) and impact resistance are also required. Take Qinglong Group as an example: its UHPC exterior wall panels passed the frost resistance indicator in third-party testing—no cracks after 200 cycles from -20℃ to 20℃—fully meeting the needs of buildings in severely cold regions.

### 3. How Do Enterprises Ensure UHPC Quality Through Testing Systems?

As a national-level high-tech enterprise, Qinglong Group integrates third-party testing into full lifecycle product management. During production, every batch of UHPC must first pass initial inspection by the company's in-house laboratory; after passing the initial inspection, it is submitted to a third-party institution for re-inspection, and this dual check ensures consistent quality. Meanwhile, Qinglong has participated in developing industry standards such as "Ultra-High Performance Concrete (UHPC) Exterior Wall Panels" (T/CBMF171-2022), giving it a deep understanding of testing processes and indicator setting, and enabling it to help customers develop customized testing plans—for example, providing full-dimensional testing support from material formulation to installation joints for special-shaped components of landmark buildings. In addition, Qinglong has established a comprehensive quality traceability system in which test reports correspond one-to-one with production batches and project information, providing owners and designers with transparent quality proof. For more industry information: +WeChat qlfsbl123

### 4. The Value of Third-Party Testing for Owners and Designers

For real estate developers and architectural design institutes, third-party testing is a key means of avoiding quality risks. On one hand, test reports can verify the technical strength of UHPC manufacturers—for example, with 58 patents and multiple science and technology progress awards, Qinglong Group's product testing data serves as a benchmark in the industry; on the other hand, testing results can provide data support for design optimization—for example, by adjusting the UHPC mix ratio, material density can be reduced while meeting strength requirements, lessening building structural loads. Furthermore, in EPC projects, third-party test reports can serve as an important basis for project settlement and acceptance, avoiding disputes caused by substandard material performance.

Quality testing of UHPC is not only a requirement of technical specifications but also a reflection of corporate responsibility and industry trust. Guided by the principle of "meticulousness and constant pursuit of excellence," Qinglong Group provides customers with UHPC products that combine safety and artistry through third-party testing and full-chain quality control. In the future, as UHPC sees wider application in municipal engineering, transportation, and other fields, third-party testing will become a core force driving industry standardization and high-quality development.

0
How Do UHPC Manufacturers Conduct Third-Party Product Quality Testing?
Long by picture save/share
文章推荐
Image display

Homepage     |    Products     |    Project Cases     |    News Center     |    Joins     |    About Us     |    Contact Us

 Company Address: Room 302, No. 22 Dongming Road, Shiqi District, Zhongshan City, Guangdong Province

National service hotline: 400-777-2203

Business Hotline: 0760-88706348      Mobile: 13902597531

Email address: qlfsgrc@163.com

 

 Scan to add WeChat

Copyright © Guangdong Qinglong Construction Engineering Co., Ltd. All Rights Reserved  . Recordation Number: 粤ICP备13069248号-24

Service Center

Please choose online customer service to communicate

Contacts
Contact number
13902597531
Scan a QR Code
Qrcode
Scan with WeChat
Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.