Welcome to Guangdong Qinglong Construction Engineering Co., Ltd.!

Site Map   |  Contact Qinglong   | 

English
  • 中文
  • English
  • عربي
Qinglong UHPC & GRC

UHPC & GRC Complex Architecture Manufacturing

A Global Benchmark in Smart Architectural Fabrication

400-777-2203
0760-88706348
13902597531
Image display
资讯中心

What Are the Steps of GRC Installation? Detailed Analysis and Operation Guide

2026-05-04 12:56:33

Click:

In the field of architectural decoration, GRC (Glass Fiber Reinforced Concrete), with its lightweight yet high-strength properties and flexible formability, has become the ideal choice for high-end projects such as grand theaters, commercial complexes, and landmark buildings. However, the professionalism of GRC installation directly affects the final visual outcome and engineering quality. As an industry leader with 28 years of full-chain experience in UHPC/GRC/GRG/GRP materials, Qinglong Group will systematically break down the standardized steps of GRC installation, providing designers and owners with a construction guide that combines safety and aesthetic value.

I. Preliminary Preparation: Laying the Technical Foundation for GRC Installation

Successful GRC installation begins with rigorous preliminary planning. First, a detailed design review is required, combining architectural drawings with on-site measured data and using BIM technology to simulate the installation process to ensure precise alignment between GRC components and the main structure. In the Dongguan Women and Children's Activity Center project, Qinglong Group used 3D laser scanning technology to control tolerances within ±2mm, laying the foundation for subsequent installation. Next is material entry inspection, focusing on verifying the flexural strength of GRC components (which must exceed 20MPa), surface flatness, and embedded part positions, while also confirming Qinglong GRC's proprietary weather resistance test reports to ensure materials comply with the requirements of the Technical Standard for Application of Glass Fiber Reinforced Cement (GRC) in Buildings (JGJ/T423-2018).

II. Substrate Treatment: Building a Safe and Stable Installation Base

Substrate treatment is a key step in ensuring the long-term stability of GRC. Before construction, dust and oil stains on the surface of the main structure must be removed, concrete defects repaired, and a specialized bonding agent applied to enhance substrate adhesion. For high-altitude installation scenarios, Qinglong GRC uses a customized steel bracket system connected to the main structure via expansion bolts, with bracket spacing strictly controlled at 800-1200mm to ensure even load distribution. In the Nanjing Road Century Plaza renovation project, this technique effectively solved the load-bearing challenge of large-span translucent GRC components, achieving a unity of aesthetics and structural safety.

III. Precise Installation: Achieving Millimeter-Level Realization of Design Concepts

The core of GRC installation lies in precision control. Using a "bottom-to-top, center-to-both-sides" installation sequence, the verticality and flatness of components are adjusted with temporary fixing devices, with tolerances kept within 3mm/m. Qinglong Group's proprietary "3D positioning + modular splicing" technology increased the installation efficiency of over 2,000 specially shaped GRC exterior wall panels by 40% in a commercial complex project in Guangzhou. During installation, special attention must be paid to joint treatment: elastic sealant should be used for filling, with 5-8mm expansion joints reserved to prevent cracking caused by thermal deformation.

IV. Quality Acceptance and Maintenance: Quality Assurance Across the Full Life Cycle

After installation is complete, multi-dimensional quality acceptance must be carried out, including anchor point pull-out tests (tensile strength ≥15kN), surface flatness inspection, and water spray tests. Qinglong Group has established a comprehensive after-sales maintenance system, providing 5 years of regular inspection services, tracing component information via RFID chips, and promptly addressing potential hazards. Notably, GRC maintenance should avoid the use of strong acid or alkali cleaners; neutral detergent with a soft cloth is recommended to preserve its decorative effect and durability.

As a national high-tech enterprise and a participant in GRC standard development, Qinglong Group has always upheld a meticulous, excellence-driven attitude, integrating 28 years of engineering experience into every detail of GRC installation. From detailed design to after-sales maintenance, Qinglong's full-chain GRC service not only ensures the safety and beauty of projects but also drives industry standard upgrades through technological innovation. Choosing Qinglong means choosing a GRC solution that combines professional depth with practical experience, allowing every architectural concept to be realized with precision.

0
What Are the Steps of GRC Installation? Detailed Analysis and Operation Guide
Long by picture save/share
文章推荐
Image display

Home     |    Products     |    Portfolio     |    News     |    Join Us     |    About Us     |    Contact Us

 Company Address: Room 302, No. 22 Dongming Road, Shiqi District, Zhongshan City, Guangdong Province

Customer Service Hotline: 400-777-2203

Business Hotline: 0760-88706348      Mobile: 13902597531

Email : qlfsgrc@163.com

 

 Scan  WeChat

Copyright © Guangdong Qinglong Construction Engineering Co., Ltd. All Rights Reserved  . Recordation Number: 粤ICP备13069248号-24

Service Center

Please choose online customer service to communicate

Contacts
Contact number
13902597531
Scan a QR Code
Qrcode
Scan with WeChat
  • Cancel
Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.