Welcome to Guangdong Qinglong Construction Engineering Co., Ltd.!
UHPC & GRC Complex Architecture Manufacturing
A Global Benchmark in Smart Architectural Fabrication
2026-01-24 15:51:36
Click:
Before leaving the factory, UHPC components must undergo more than 20 tests across four major categories—mechanical properties, durability, dimensional tolerances, and appearance quality—to ensure products meet design and specification requirements. Based on national standards and internal control standards (20% stricter than national standards), Qinglong Group has established a complete testing process: mechanical properties include compressive strength (≥120MPa), flexural strength (≥15MPa), and elastic modulus (≥40GPa) testing; durability covers frost resistance (F300) and chloride ion diffusion coefficient (≤2.0×10⁻¹²m²/s) testing; dimensional tolerances control panel thickness at ±1mm and flatness at ≤2mm/2m; appearance must be free of color difference and cracks. At the CNAS laboratory at the Nanning production base, every batch of UHPC components is sampled and tested, with data entered into the MES system, maintaining a pass rate consistently above 99.5%. Rigorous testing is the final checkpoint for delivering reliable products.
Compressive strength is tested using 100mm cube specimens, and flexural strength using 40mm×40mm×160mm small beams. Qinglong Group has introduced a 2000kN universal testing machine with ±1% accuracy, sampling one test group for every 100m³ of components. In spot checks for the Shenzhen Yirui project, flexural strength averaged 18.3MPa, exceeding design requirements.
Frost resistance is tested by the rapid freeze-thaw method, with mass loss after 300 cycles ≤5%; the chloride ion diffusion coefficient is tested by the RCM method. For coastal projects, Qinglong Group has added salt spray tests simulating a 20-year corrosive environment.
3D dimensions are measured with laser scanners, and panels with deviations exceeding ±2mm are reworked; color is measured with a colorimeter, with ΔE≤3.0. For the Dongguan Women and Children's Activity Center project, color difference across 5,000 panels was controlled to ΔE≤1.5, achieving seamless joining.
Testing is not a cost—it is an investment. Through its comprehensive testing system, Qinglong Group ensures customers can trust every panel they receive.