The conventional thickness of UHPC curtain wall panels ranges from 15-30mm, determined by panel size, support conditions, and wind pressure. A panel thickness of 15mm is suitable for panel sizes ≤1.2m and wind pressures ≤1.5kPa; a thickness of 20mm is suitable for panel sizes ≤1.8m and wind pressures ≤2.5kPa; a thickness of 30mm is suitable for panel sizes ≤2.4m and wind pressures ≤3.5kPa. This thickness design ensures both safety and economic rationality.
When selecting thickness, structural calculations are required, including wind pressure resistance calculations, seismic calculations, and deformation verification. For example, a 1.5m×3m panel in an area with a basic wind pressure of 0.5kPa can meet the requirements with a 20mm thickness, with deflection ≤L/250, stress ≤10MPa, and a safety factor >3. This scientific design ensures the curtain wall is safe and reliable.
Panel size: the larger the panel, the greater the thickness; wind pressure: the higher the wind pressure, the greater the thickness; these criteria ensure safety.
Wind pressure resistance calculation; seismic calculation; deformation verification; these calculations ensure reliability.
Optimize thickness on the premise of safety; avoid excessive conservatism; these considerations save costs.
Panel size 1.5m×3m, wind pressure 0.5kPa, thickness 20mm; these cases verify the rationality.
Thickness design requires professional calculation. Qinglong UHPC features scientific design that is safe and economical.