How Many Orders of Magnitude Higher Is the Impermeability of UHPC Than Ordinary C80 Concrete?

2025-12-16 17:07:33

Click:

UHPC achieves an order-of-magnitude improvement in impermeability: the chloride ion diffusion coefficient is 1/100 that of C80 concrete (0.2×10⁻¹² vs 2×10⁻¹² m²/s), the electric flux value is only 1/50 of C80 (200 vs 1000 coulombs), and water absorption is reduced to 1/8 (0.8% vs 6%). This improvement stems from a qualitative change in pore structure—the proportion of harmful pores (>50nm) drops from 12% to below 2%.

In the Qingdao Jiaozhou Bay cross-sea project, Qinglong UHPC revetment components have withstood 10 years of marine environment exposure. Core drilling inspection shows a chloride ion penetration depth of only 1.8mm, 1/8 that of C80 components from the same period (penetration depth 15mm). Electron microscopy analysis confirms that UHPC pore diameters are concentrated in the 10-20nm range, with a tortuosity of 158, compared to 32 for C80 concrete. This dense structure extends the predicted service life from 50 years to 100 years with maintenance-free operation throughout, reducing full life-cycle costs by 40%.

Pore Structure Optimization Mechanism

Maximum packing density theory reduces total porosity to 3%. Nano fillers bring the peak pore diameter to 15nm. Polymer fibers form a micropore blocking network. Autogenous shrinkage compensation refines the pore structure.

Permeability Coefficient Comparison

Water permeability coefficient: UHPC 1×10⁻¹⁵ m/s, C80 1×10⁻¹² m/s. Chloride ion diffusion coefficients differ by 100 times. Oxygen permeability differs by 200 times. These differences determine the durability gap.

Differences in Testing Methods

UHPC uses the 90-day electric flux method (≤500C). C80 commonly uses the 28-day RCM method (≤1000C). Water absorption testing requires 28 days of saturation. Relevant conversion formulas have been established.

Engineering Verification Data

Marine engineering: 10-year penetration depth ≤2mm. Scaling resistance in deicing salt environments improved 5 times. In freeze-thaw zones, dynamic elastic modulus retention ≥95% after 300 cycles. These data verify the superiority.

Impermeability requires systematic design. Through 28 years of engineering practice, Qinglong UHPC has established a complete durability design system.

0
How Many Orders of Magnitude Higher Is the Impermeability of UHPC Than Ordinary C80 Concrete?
Long by picture save/share
文章推荐
Image display

Homepage     |    Products     |    Project Cases     |    News Center     |    Joins     |    About Us     |    Contact Us

 Company Address: Room 302, No. 22 Dongming Road, Shiqi District, Zhongshan City, Guangdong Province

National service hotline: 400-777-2203

Business Hotline: 0760-88706348      Mobile: 13902597531

Email address: qlfsgrc@163.com

 

 Scan to add WeChat

Copyright © Guangdong Qinglong Construction Engineering Co., Ltd. All Rights Reserved  . Recordation Number: 粤ICP备13069248号-24

Service Center

Please choose online customer service to communicate

Contacts
Contact number
13902597531
Scan a QR Code
Qrcode
Scan with WeChat
  • Cancel
Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.